[ Identification | Description | Input parameters | Output parameters | Links ]

The Test_Monochromators Instrument

Compares intensities of Monochromator components.

Identification

Description


Very simple setup to compare intensities diffracted by Monochromators. 
It shows that implementations are equivalent.

Example: Mono=6 Detector: psd1_I=9.21295e-05

Input parameters

Parameters in boldface are required; the others are optional.
Name Unit Description Default
Mono - Choice of Monochromator component to use, with 1=Monochromator_flat 2=Monochromator_pol 3=Monochromator_pol (forcing 1% events to be reflected) 4=Monochromator_curved (in flat mode) 5=Monochromator_2foc (contrib, flat mode) 6=Single_crystal 1
lambda Angs Source wavelength 2.0
Moz Arc minutes Mosaicity 40
PG 0
powder 0
order 1

Links


[ Identification | Description | Input parameters | Output parameters | Links ]

Generated automatically by McDoc, Peter Willendrup <peter.willendrup@risoe.dk> / Wed Sep 5 11:20:18 2018